The books · reading order

BuildGrid Data Centre Engineering Series

Start with Book 1, then Book 2. Book 1 covers cooling from first principles up to the air-to-liquid boundary; Book 2 goes deep on single-phase direct-to-chip liquid cooling.

Book 1 · Start here

Data Centre Cooling Fundamentals: An Engineering Introduction to Air, Chilled Water and Liquid Cooling

By BuildGrid Consultancy

Cooling from first principles up to the air-to-liquid boundary.

84 pages · 11 parts
25 engineering figures · 9 worked examples · 40 review questions with answer notes. Every part ends with a summary and review questions.

For: electrical and HVAC engineers, IT and facilities teams, project managers, commissioning technicians, investors and students.

English · Independently published
Published 8 Nov 2026
ISBN-13 979-8140866839

Amazon.fr pricesKindle €8.97 / Paperback €28.40
Book 1 · Contents
PART IWhy Data Centres Need Cooling
PART IIHeat Transfer Essentials
PART IIIThe IT Environment
PART IVAir Cooling and Airflow Management
PART VChilled Water Systems
PART VIHeat Rejection and Free Cooling
PART VIIAn Introduction to Liquid Cooling
PART VIIIRedundancy, Controls and Resilience
PART IXEnergy and Efficiency
PART XFrom Design to Operation
PART XIReference Data
Book 2 · BuildGrid Data Centre Engineering Series

Everything that governs a liquid cooling project, in one reference.

What's inside

Eleven parts, written for engineers who have to decide

Each part builds on the last: the physics that sets the boundaries, the components that live inside them, and the delivery reality that decides whether any of it works on site.

One example of what's inside. A direct-to-chip cold plate captures roughly 70–80% of a rack's heat. On a 120 kW rack that leaves 25–35 kW still going into the air — in rooms where the air system was quietly downsized because "it's liquid cooled now." That single ratio decides your CRAH sizing, your containment, and your real usable density. Part I.

Engineering tools

Calculation tools that work like software

Guided inputs, protected formulas, a built-in user guide and client-ready outputs. One-time purchase, lifetime updates.

Payment and delivery handled securely by Gumroad. Every purchase includes a licence key and lifetime access to updates.

Free resources

Start here — no charge

Use them on your own projects. They are also the best way to see how the paid material is written before you buy anything.

About

Written from the field, not from a brochure

BuildGrid publishes engineering references and calculation tools for datacenter cooling. Everything here is written by a practising datacenter cooling engineer working daily on live DLC, chilled-water and CRAH projects — from tender through commissioning.

That matters because most available material is either vendor marketing or academic theory. This sits in between: what the physics requires, what the equipment actually does, and what goes wrong when the two are assumed to match.

Every figure is traceable. Where a number comes from a standard, a manufacturer's data or a published correlation, it is referenced. Where a value is illustrative, it says so. Nothing is presented as certified data that isn't.

Studies too. Fixed-price, fixed-deadline engineering studies — design reviews, DLC readiness, due diligence — remain available. See the consultancy services →